Four slab-column subassemblages, modeled after a typical reinforced flat plate building, are tested under combined gravity and lateral loads. The testing program incorporates two levels of gravity loads and compares the effects of biaxial versus uniaxial lateral loading on connection behavior. To study the effectiveness of connection repair, one of the tested specimens is repaired with epoxy/grout and reloaded. The post failure behavior of slab-column connections is investigated and the adequacy of slab reinforcement detailing in preventing progressive collapse is assessed. Existing strength and lateral stiffness models are compared with experimental results. Data from past research are collected to investigate the ductility and drift capacity of slab-column connections. The seismic design of reinforced concrete flat slab buildings is discussed.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 6 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |