Criteria recommended by ACI Committee 408 on development and lap splice length design for straight reinforcing bars in tension are presented in code format and compared with those in ACI 318-05, Building Code Recommendations for Structural Concrete. The recommended criteria produce designs with improved reliability compared to those in ACI 318. Development lengths are longer than those in ACI 318 for conditions of low cover or confinement, but shorter for bars with higher degrees of confinement, provided by added cover and transverse reinforcement and wider spacing between bars, and for normalweight concretes with strengths between 10,000 and 16,000 psi (70 and 110 MPa).
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 10 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |