doi: 10.14311/552
This paper presents a computer-aided design of a transformer station grounding system. Fault conditions in a transformer station can produce huge damage to transformer station equipment if the grounding system is not designed properly. A well designed grounding system is a very important part of the project for transformer station design as a whole. This paper analyses a procedure for transformer grounding system design and spatial distribution of touch and step voltage on the ground surface level, using the CDEGS (Current Distribution Electromagnetic Interference Grounding and Soil Structure Analysis) software. Spatial distribution is needed for checking and finding dangerous step and touch voltages above and around the transformer station. Apparent earth resistivity data is measured and analyzed using the RESAP module of the CDEGS software. Because of the very high current flow into the grounding system during a single line to ground fault or a three phase fault in the transformer station, very high and dangerous potentials can be induced on the metallic structures including the fence, which can cause dangerous situations for people and animals near the station and for the personnel inside the station. The PLOT module of CDEGS is used to view the results of the scalar potential, step and touch voltage on the surface. Graphic displays include equipotent contour lines and potential profiles (gradients) in 3D and 2D perspective and apparent soil resistivity (Wm) versus inter electrode spacing (m). The results of alternative grid designs may be displayed simultaneously for the purpose of comparison.
safety, substation, souil, touch and step voltage, Computer-aided design, grounding grid, Engineering (General). Civil engineering (General), step and touch voltage, computer-aided design, soil, computer-aided design; substation; grounding grid; soil; safety; touch and step voltage, Computer-aided design ; substation ; grounding grid ; souil ; safety ; step and touch voltage, TA1-2040
safety, substation, souil, touch and step voltage, Computer-aided design, grounding grid, Engineering (General). Civil engineering (General), step and touch voltage, computer-aided design, soil, computer-aided design; substation; grounding grid; soil; safety; touch and step voltage, Computer-aided design ; substation ; grounding grid ; souil ; safety ; step and touch voltage, TA1-2040
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |