doi: 10.14311/1594
This paper deals with the control parameters for selected geometric accuracy measurements for a machine tool. The parameters were needed after a refurbished milling machine was purchased. After setting up the machine, it was necessary to check the geometric accuracy that can be used for precise milling. The whole check was performed in accordance with ISO 10791. Only selected parameters of geometric accuracy were inspected, and they were later compared with the prescribed values. On the basis of a comparison of these values we were able to determine whether the machine tool can be used for accurate machining.
geometric accuracy, TA1-2040, milling machine, Engineering (General). Civil engineering (General), testing
geometric accuracy, TA1-2040, milling machine, Engineering (General). Civil engineering (General), testing
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |