Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao CHEST Journalarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
CHEST Journal
Article . 2005 . Peer-reviewed
License: Elsevier TDM
Data sources: Crossref
CHEST Journal
Article . 2005
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Choice of Oximeter Affects Apnea-Hypopnea Index

Authors: Subooha, Zafar; Indu, Ayappa; Robert G, Norman; Ana C, Krieger; Joyce A, Walsleben; David M, Rapoport;

Choice of Oximeter Affects Apnea-Hypopnea Index

Abstract

Current Medicare guidelines include an apnea-hypopnea index (AHI) > or = 15 events per hour, in which all hypopneas must be associated with 4% desaturation, to qualify for reimbursement for therapy with continuous positive airway pressure (CPAP). The present data demonstrate the effect of pulse oximeter differences on AHI.Prospective study, blinded analysis.Academic sleep disorder center.One hundred thirteen consecutive patients (84 men and 29 women) undergoing diagnostic sleep studies and being evaluated for CPAP based on the Medicare indications for reimbursement.Patients had two of four commonly used oximeters with signal averaging times of 4 to 6 s placed on different digits of the same hand during nocturnal polysomnography.Apneas and candidate hypopneas (amplitude reduction, > 30%) were scored from the nasal cannula airflow signal without reference to oximetry. Candidate hypopneas then were reclassified as hypopneas by each oximeter if they were associated with a 4% desaturation. Although the use of three oximeters resulted in a similar AHI (bias, or = 15 events per hour (meeting the Medicare criteria for treatment) by one oximeter but not when a different oximeter was used. More importantly, when our analysis was limited to those patients whose number of candidate hypopneas made them susceptible to the threshold value of 15 events per hour, 7 of 35 patients who did not meet the Medicare AHI standard for treatment by one oximeter were reclassified when a different oximeter was used.In the present study, oximeter choice affected whether the AHI reached the critical cutoff of 15 events per hour, particularly in those with disease severity that was neither very mild nor very severe. As oximetry is not a technique that produces a generic result, there are significant limitations to basing the definition of hypopnea on a fixed percentage of desaturation in determining the eligibility for CPAP therapy.

Related Organizations
Keywords

Oxygen, Sleep Apnea Syndromes, Polysomnography, Humans, Signal Processing, Computer-Assisted, Oximetry, Prospective Studies, Medicare, United States

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    58
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
58
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!