Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Annals of Pharmacoth...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
versions View all 2 versions
addClaim

Comparing Direct Thrombin Inhibitors Using aPTT, Ecarin Clotting Times, and Thrombin Inhibitor Management Testing

Authors: Robert C, Gosselin; Jeffrey H, King; Kim A, Janatpour; William E, Dager; Edward C, Larkin; John T, Owings;

Comparing Direct Thrombin Inhibitors Using aPTT, Ecarin Clotting Times, and Thrombin Inhibitor Management Testing

Abstract

BACKGROUND: Patients with heparin-induced thrombocytopenia and thrombosis may be acutely anticoagulated with direct thrombin inhibitors (DTIs). The anticoagulation is typically monitored using the activated partial thromboplastin time (aPTT) or ecarin clotting time (ECT). OBJECTIVE: To compare 14 methods for measuring aPTT, as well as ECT and thrombin inhibitor management test (TIM), in samples containing DTIs. METHODS: DTIs were added to pooled normal plasma to achieve low (0.1–1.2 μg/mL) and high (1.5–8.0 μg/mL) drug concentrations. Each low-concentration DTI sample was tested using all aPTT reagents, while each low- and high-concentration DTI was tested using the ECT and TIM. RESULTS: All aPTT reagents had a significant dose-dependent correlation with drug concentration. Only Actin FSL and APTT-S demonstrated equivalent aPTT ratios obtained from any DTI. The TAS-aPTT was the most sensitive aPTT reagent to argatroban, with the aPTT ranging from 52.7 to 121.2 seconds corresponding to 0.1 to 1.2 μg/mL of drug concentration. The TAS-aPTT and Pathromtin were the most sensitive aPTT reagents to bivalirudin, with aPTTs of 87.4 seconds and 101.5 seconds, respectively, at 1.2 μg/mL of drug. Pathromtin was the most sensitive aPTT reagent to lepirudin, with a maximum aPTT of 108.9 seconds at 1.2 μg/mL of drug. There was no statistically significant difference between the TIM and ECT clotting times for each DTI. Lepirudin and bivalirudin ECT and TIM clotting times were equivalent. CONCLUSIONS: There are unique differences between reagent manufacturers in the monitoring of DTIs. Acceptable alternatives to aPTT monitoring of DTI anticoagulation include the ECT and TIM.

Keywords

Sulfonamides, Dose-Response Relationship, Drug, Thrombin, Hirudins, In Vitro Techniques, Arginine, Peptide Fragments, Recombinant Proteins, Fibrinolytic Agents, Pipecolic Acids, Endopeptidases, Humans, Partial Thromboplastin Time, Blood Coagulation

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    48
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
48
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!