Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

RAINFALL SIMULATOR FOR LABORATORY STUDIES

Authors: null T. P. Regmi; null A. L. Thompson;

RAINFALL SIMULATOR FOR LABORATORY STUDIES

Abstract

Numerous types of rainfall simulators have been used to study the fundamental behavior of sediment transfer and chemical movement in soil from rainfall. For results of these studies to be representative, it is essential that the artificial rainfall have characteristics similar to that of natural rainfall. In this study, a number of design modifications were made to a stationary rainfall device in order to achieve rainfall simulation comparable to natural rainfall. A 1 m × 1 m laboratory-scale rainfall simulator was designed and constructed using the positive volume displacement principle to provide a precise and broad range of rainfall intensities from 0.025 to 16 cm/h in increments of 0.025 cm/h. The drop-forming mechanism consisted of a telescopic arrangement of 21 and 9 gauge stainless steel tubings, producing a mean droplet diameter of 4.5 mm. A drop-size distribution with characteristics similar to natural rainfall was produced when droplets passed through a suspended drop redistribution screen. When the droplet size spectrum for different height of screen suspension was mapped with the spectrum produced by different intensities of natural rainfall, it was possible to estimate a height of suspension corresponding to a desired application rate with characteristics similar to natural rainfall at that given rate. The fully automated rainfall simulator was arranged in a closed loop using a feed tank and automated solenoid valves. The entire rainfall simulation system was installed at a height of 14 m to allow droplets up to 4.3 mm diameter to reach 95% of their respective terminal velocities. Flow rate variation among the 216 individual drippers, used in the rainfall simulation design, was less than 15% of the mean at system application rates less than 1.5 cm/h, and less than 9% at rates greater than 8 cm/h. Reproducibility of system application rate for a given air inlet tube position was within 1%. The best commercial unit available had an advertised ± 20% variation in system application rate with only 50% of the range in rate of the unit developed here.

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    29
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
29
Top 10%
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!