Abstract Context Parathyroid tissue is one of the few tissues to have strong near-infrared (NIR) autofluorescence, which has been exploited to improve intraoperative parathyroid identification. The US Food and Drug Administration has approved 2 devices for this purpose. Adrenal glands can be difficult to distinguish from surrounding fat, an issue during total adrenalectomy. Objective We hypothesized adrenal tissue may also possess considerable NIR autofluorescence. Methods Resected patient adrenal specimens were examined after robotic adrenalectomy with an NIR camera intraoperatively. Patients did not receive fluorescent dye. Images were taken of both gross and sectioned specimens. Post hoc image analysis was performed with ImageJ software. Confocal microscopy was performed on selected tissues using immunofluorescence and hematoxylin-eosin staining. Results Resected tissue was examined from 22 patients undergoing surgery for pheochromocytomas (6), primary aldosteronism (3), adrenocorticotropin-independent hypercortisolism (10), and a growing or suspicious mass (3). Normal adrenal tissue demonstrated strong NIR autofluorescence. The intensity ratio compared to background (set as 1) for gross images was 2.03 ± 0.51 (P < .0001) compared to adjacent adipose of 1.24 ± 0.18. Autofluorescence from adrenal tumors was also detected at variable levels of intensity. Cortisol-producing tumors had the highest fluorescence ratio of 3.01 ± 0.41. Confocal imaging localized autofluorescence to the cytosol, with the highest intensity in the zona reticularis followed by the zona fasciculata. Conclusion Normal and abnormal adrenal tissues possess natural NIR autofluorescence. Highest autofluorescence levels were associated with cortisol-producing tumors. Confocal imaging demonstrated the highest intensity in the zona reticularis. NIR cameras may have the potential to improve identification of adrenal tissue during surgery.
Clinical Research Article
Clinical Research Article
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 6 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |