</script>Rapid immunochromatographic tests (ICT) for dengue non-structural protein 1 (NS1) have shown good performance for diagnosing acute-phase dengue in serum in laboratory settings, but rarely have been assessed in whole blood and at point of care (POC). This study compare the accuracy and inter- and intra-observer reliability of the NS1 Bioeasy™ ICT in whole blood at POC versus serum in the laboratory, during a DENV-1 epidemic.Cross-sectional study involving 144 adults spontaneously demanding care in an emergency department within 4 days of onset of acute febrile illness. Accuracy of NS1 Bioeasy™ ICT was compared in whole blood and serum, both at 15 and 30 min, blinded to the reference RT-PCR or NS1 ELISA. Non-dengue patients were also tested for Zika virus with RT-PCR. Reliability of whole blood and serum readings by the same or different observers was measured by simple kappa (95% CI).At 15 min, sensitivity (Sn) of NS1 Bioeasy™ ICT in whole blood/POC was 76.7% (95% CI: 68.0-84.1) and specificity (Sp) was 87.0% (95% CI: 66.4-97.2). Sn in serum/laboratory was 82% (95% CI: 74.1-88.6) and Sp 100% (95% CI: 85.8-100). Positive likelihood ratio was 5.9 (95% CI: 2.0-17.0) for whole blood/POC and 19.8 (95% CI: 2.9-135.1) for serum/laboratory. Reliability of matched readings of whole blood/POC and serum/laboratory by the same observer (k = 0.83, 95% CI: 0.74-0.93) or different observers (k = 0.81, 95% CI: 0.72-0.92) was almost perfect, with higher discordant levels in the absence of dengue. Results did not differ statistically at 5%.NS1 Bioeasy™ ICT in DENV-1 epidemics is a potentially confirmatory test. Invalid results at 15 min should be reread at 30 min. To optimize impact of implementing ICT in the management of false-negatives it should be incorporated into an algorithm according to setting and available specimen.UTN U1111-1145-9451 .
Reproducibility of results, Adult, Male, Adolescent, Point-of-Care Systems, NS1, Enzyme-Linked Immunosorbent Assay, Infectious and parasitic diseases, RC109-216, Viral Nonstructural Proteins, Sensitivity and Specificity, Dengue, Young Adult, Diagnosis, Humans, Prospective Studies, Aged, Aged, 80 and over, Reproducibility of Results, Dengue Virus, Middle Aged, Sensitivity and specificity, Cross-Sectional Studies, Point-of-care systems, Female, Brazil, Research Article
Reproducibility of results, Adult, Male, Adolescent, Point-of-Care Systems, NS1, Enzyme-Linked Immunosorbent Assay, Infectious and parasitic diseases, RC109-216, Viral Nonstructural Proteins, Sensitivity and Specificity, Dengue, Young Adult, Diagnosis, Humans, Prospective Studies, Aged, Aged, 80 and over, Reproducibility of Results, Dengue Virus, Middle Aged, Sensitivity and specificity, Cross-Sectional Studies, Point-of-care systems, Female, Brazil, Research Article
| citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 11 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |