Transfemoral Internal Thoracic (Mammary) Arteriography

Authors: C H, Dart; S M, Scott; T, Takaro;

Transfemoral Internal Thoracic (Mammary) Arteriography

Abstract

The use of arteriography in the evaluation of myocardial implants and coronary arteries is increasing. Transbrachial selective catheterization of the internal thoracic (mammary) artery (4), first described by Arner (1), has been used to evaluate internal thoracic arterial implants in the myocardium (2, 3). Odman (6) demonstrated that percutaneous catheterization of the main branches of the aorta is feasible, and recently Judkins (5) reported this modification of Seldinger's technic (7) for transfemoral coronary arteriography. This paper presents a method of selectively catheterizing both internal thoracic arteries and the coronary arteries at one examination, using the transfemoral Seldinger technic. This procedure was developed for a number of reasons: (a) the need for arteriographic evaluation of bilateral internal thoracic arterial implantation in the myocardium; (b) the difficulty in using the left brachial retrograde approach for left internal thoracic arteriography following arteriographic or local ...

Keywords

Femoral Artery, Thoracic Arteries, Angiography, Methods, Humans, Coronary Disease, Coronary Angiography, Catheterization

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!