doi: 10.1148/103.2.443
pmid: 5024575
Abstract A new field flattening filter was designed and constructed for the Varian Clinac-4 Linear Accelerator. Design considerations led to the construction of a conically shaped filter made of 94% lead and 6% antimony. The resultant beam profiles and isodose distributions are compared to those obtained with the brass filter supplied with the accelerator. The new filter resulted in improved dose distributions with reduced penumbra, increased depth dose, and more skin sparing at a cost of 10% reduction in the peak output of the x-ray beam.
Antimony, Lead, Radiotherapy, Radiometry, Filtration
Antimony, Lead, Radiotherapy, Radiometry, Filtration
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 20 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 1% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |