Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Veterinary Recordarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Veterinary Record
Article . 2017 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
versions View all 2 versions
addClaim

Comparison of a 5‐mm and 10‐mm vessel sealing device in an open ovariectomy model in dogs

Authors: N, Devriendt; B, Van Goethem; L, Van Brantegem; M, De Ridder; A, Kitshoff; M, Or; H, de Rooster;

Comparison of a 5‐mm and 10‐mm vessel sealing device in an open ovariectomy model in dogs

Abstract

The objectives of this study were to compare (1) the extent of thermal damage and (2) the time between the 5‐mm LigaSure V (LS5) and 10‐mm LigaSure Atlas (LS10) vessel sealing devices (VSD) when performing open ovariectomy in dogs. A prospective, randomised, clinical trial was performed in 40 client‐owned sexually entire female dogs. In each dog, one ovary was randomly assigned to be surgically removed using LS5 and the contralateral using LS10. The depth of thermal spread, measured on histopathological preparations, was significantly larger for LS10 (LS10 1.35±0.23 mm v LS5 0.82±0.10 mm; P<0.001). Mean ovariectomy time was significantly faster when using LS10 (LS5 2.58±1.32 minutes v LS10 2.07±1.27 minutes; P=0.008). Bodyweight was positively correlated with the time required for ovariectomy using LS5 (P=0.004), but no such correlation was present for LS10 (P=0.611). In conclusion, during open ovariectomy using VSD, LS10 causes significantly more thermal spread but surgical time is shorter compared with LS5. When using LS5, the ovariectomy time increases with increasing bodyweight.

Related Organizations
Keywords

Hot Temperature, Ovariectomy, Operative Time, Surgical Instruments, Hemostasis, Surgical, Dogs, Treatment Outcome, Animals, Female, Prospective Studies, Ligation

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    6
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
6
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!