A microelectromechnical-loudspeaker based on the magnetostrictive effect is presented. The membrane consists of a comb structure of monomorph bending cantilevers with an area of about 16 mm2. Prototypes generate a sound pressure level (SPL) of up to 102 dB at 450 Hz with a total harmonic distortion of 2% inside a 2 cm3 measurement volume. The fabrication process of the device as well as a coupled simulation model to calculate its sound pressure is introduced. The model reproduces the measurements and is employed to further optimize the loudspeaker membrane. As a result, a computed maximum SPL of 106 dB has been achieved with a −6 dB frequency range extending from 100 Hz to 2.6 kHz.
| citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 8 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |