Laparoscopic partial kidney ablation using high-intensity focused ultrasound

Authors: Jahangir Tavakkoli; Victor V. Rao; Ralf Seip; Narendra T. Sanghvi; Eric Barret; Arieh L. Shalhav;

Laparoscopic partial kidney ablation using high-intensity focused ultrasound

Abstract

A laparoscopic ultrasound probe was developed for image-guided high-intensity focused ultrasound (HIFU) ablation of renal tissue. The probe expands the application of a commercially available HIFU system (SonablateTM) to laparascopic operations. It consists of a 4-MHz focused rectangular HIFU piezoceramic transducer (30×10 mm, FL=30 mm) confocally coupled with a circular central element (8 mm in diameter) used for real-time pulse-echo imaging during treatment. Precise mechanical movements of the transducer enable it to treat targeted tissue volumes. The probe was fully characterized by measuring its electrical impedance, acoustic field, and total acoustic power output. Moreover, the acoustic field was simulated using an analytical model. The laparoscopic probe was able to generate acoustic power levels up to 35 W that correspond to focal intensities over 2200 W/cm2 in tissue, sufficient for tissue ablation through rapid temperature rise (>90<th>°C) and cavitation mechanisms. The probe was tested in an in vivo animal study in which 15 pigs were treated through a sterile laparoscopic procedure. A lesion with dimensions of 23×17×11 mm ±1 mm was successfully generated in the left kidney of each pig during a treatment time of less than 30 min. Histology results demonstrated homogeneous well-delineated lesions generated in the target region.

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    1
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
1
Average
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!