
doi: 10.1121/1.428318
pmid: 10641658
The pulsation threshold technique was used to estimate the basilar-membrane (BM) response to a tone at characteristic frequency (CF). A pure-tone signal was alternated with a pure-tone masker. The frequency of the masker was 0.6 times that of the signal. For signal levels from around 20 dB above absolute threshold to 85 dB SPL, the masker level was varied to find the level at which a transition occurred between the signal being perceived as “pulsed” or “continuous” (the pulsation threshold). The transition is assumed to occur when the masker excitation is somewhat greater than the signal excitation at the place on the BM tuned to the signal. If it is assumed further that the response at this place to the lower-frequency masker is linear, then the shape of the masking function provides an estimate of the BM response to the signal. Signal frequencies of 0.25, 0.5, 1, 2, 4, and 8 kHz were tested. The mean slopes of the masking functions for signal levels between 50 and 80 dB SPL were 0.76, 0.50, 0.34, 0.32, 0.35, and 0.41, respectively. The results suggest that compression on the BM increases between CFs of 0.25 and 1 kHz and is roughly constant for frequencies of 1 kHz and above. Despite requiring a subjective criterion, the pulsation threshold measurements had a reasonably low variability. However, the estimated compression was less than in an earlier study using forward masking. The smaller amount of compression observed here may be due to the effects of off-frequency listening.
physiology: Perceptual Masking, Adult, Auditory Threshold, Middle Aged, physiology: Auditory Perception, Basilar Membrane, physiology: Auditory Threshold, physiology: Basilar Membrane, Auditory Perception, Humans, Perceptual Masking
physiology: Perceptual Masking, Adult, Auditory Threshold, Middle Aged, physiology: Auditory Perception, Basilar Membrane, physiology: Auditory Threshold, physiology: Basilar Membrane, Auditory Perception, Humans, Perceptual Masking
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 57 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
