Vibrotactile thresholds were measured on the thenar eminence and the volar forearm at different static depths of skin indentation. Three stimulus frequencies (1, 20, and 200 Hz) were delivered through either a 0.008- or a 2.9-cm2 contactor. The indentation depths ranged from 0 to 1 mm (0.25-mm steps) relative to the point of skin contact with the stimulator. There was a significant effect of indentation in all stimulus combinations of contactor size, location, and frequency. These results resolve an apparent discrepancy in the literature regarding threshold reduction with increasing contactor size observed on the forearm at low frequencies.
Adult, Male, Touch, Psychophysics, Differential Threshold, Humans, Female, Vibration
Adult, Male, Touch, Psychophysics, Differential Threshold, Humans, Female, Vibration
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 18 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |