Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Medical Physicsarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Medical Physics
Article . 2000 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
Medical Physics
Article . 2000
versions View all 2 versions
addClaim

High temporal resolution for multislice helical computed tomography

Authors: K, Taguchi; H, Anno;

High temporal resolution for multislice helical computed tomography

Abstract

Multislice helical computed tomography (CT) substantially reduces scanning time. However, the temporal resolution of individual images is still insufficient for imaging rapidly moving organs such as the heart and adjacent pulmonary vessels. It may, in some cases, be worse than with current single‐slice helical CT. The purpose of this study is to describe a novel image reconstruction algorithm to improve temporal resolution in multislice helical CT, and to evaluate its performance against existing algorithms. The proposed image reconstruction algorithm uses helical interpolation followed by data weighting based on the acquisition time. The temporal resolution, the longitudinal (z‐axis) spatial resolution, the image noise, and the in‐plane image artifacts created by a moving phantom were compared with those from the basic multislice helical reconstruction (helical filter interpolation, HFI) algorithm and the basic single‐slice helical reconstruction algorithm (180° linear interpolation, 180LI) using computer simulations. Computer simulation results were verified with CT examinations of the heart and lung vasculature using a 0.5 second multislice scanner. The temporal resolution of HFI algorithm varies from 0.28 and 0.86 s, depending on helical pitch. The proposed method improves the resolution to a constant value of 0.29 s, independent of pitch, allowing moving objects to be imaged with reduced blurring or motion artifacts. The spatial (z) resolution was slightly worse than with the HFI algorithm; the image noise was worse than with the HFI algorithm but was comparable to axial (step‐and‐shoot) CT. The proposed method provided sharp images of the moving objects, portraying the anatomy accurately. The proposed algorithm for multislice helical CT allowed us to obtain CT images with high temporal resolution. It may improve the image quality of clinical cardiac, lung, and vascular CT imaging.

Related Organizations
Keywords

Male, Aortic Aneurysm, Thoracic, Phantoms, Imaging, Biophysics, Heart, Middle Aged, Pulmonary Artery, Biophysical Phenomena, Aortic Dissection, Evaluation Studies as Topic, Humans, Radiographic Image Interpretation, Computer-Assisted, Female, Tomography, X-Ray Computed, Lung, Algorithms

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    119
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 1%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
119
Top 10%
Top 1%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!