
doi: 10.1118/1.3501313
pmid: 21158279
Purpose:A project to construct a new treatment facility, as an extension of the existing HIMAC facility, has been initiated for the further development of carbon‐ion therapy at NIRS. This new treatment facility is equipped with a 3D irradiation system with pencil‐beam scanning. The challenge of this project is to realize treatment of a moving target by scanning irradiation. To achieve fast rescanning within an acceptable irradiation time, the authors developed a fast scanning system.Methods:In order to verify the validity of the design and to demonstrate the performance of the fast scanning prior to use in the new treatment facility, a new scanning‐irradiation system was developed and installed into the existing HIMAC physics‐experiment course. The authors made strong efforts to develop (1) the fast scanning magnet and its power supply, (2) the high‐speed control system, and (3) the beam monitoring. The performance of the system including 3D dose conformation was tested by using the carbon beam from the HIMAC accelerator.Results:The performance of the fast scanning system was verified by beam tests. Precision of the scanned beam position was less than ±0.5 mm. By cooperating with the planning software, the authors verified the homogeneity of the delivered field within ±3% for the 3D delivery. This system took only 20 s to deliver the physical dose of 1 Gy to a spherical target having a diameter of 60 mm with eight rescans. In this test, the average of the spot‐staying time was considerably reduced to, while the minimum staying time was .Conclusions:As a result of this study, the authors verified that the new scanning delivery system can produce an accurate 3D dose distribution for the target volume in combination with the planning software.
Time Factors, Radiotherapy Planning, Computer-Assisted, Dose-Response Relationship, Radiation, Heavy Ion Radiotherapy, Radiotherapy Dosage, Equipment Design, Radiation Dosage, Magnetics, Electromagnetic Fields, Imaging, Three-Dimensional, Radiation Oncology, Humans, Algorithms, Software
Time Factors, Radiotherapy Planning, Computer-Assisted, Dose-Response Relationship, Radiation, Heavy Ion Radiotherapy, Radiotherapy Dosage, Equipment Design, Radiation Dosage, Magnetics, Electromagnetic Fields, Imaging, Three-Dimensional, Radiation Oncology, Humans, Algorithms, Software
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 163 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 1% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 1% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
