Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Medical Physicsarrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Medical Physics
Article . 2006 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
versions View all 1 versions
addClaim

SU‐FF‐I‐19: A Study of Megavoltage Beam Tomosynthesis

Authors: J Zhang; D Godfrey; F Yin;

SU‐FF‐I‐19: A Study of Megavoltage Beam Tomosynthesis

Abstract

Purpose: To study the impact of projection numbers on the quality of tomosynthesis images using megavoltage beams. Method and Materials: It has been shown that isocentric kilovoltage tomosynthesis images can be generated with no more than 50 degree scan angle. With only one seventh of scan time and dose of CBCT, this new technology can generate on‐board images with comparable quality as CBCT to guide patient's positioning. In this study, we used megavoltage (MV) beam projections to reconstruct tomosynthesis images. The MV projection images were acquired by using a MV portal imager mounted on a Varian‐21EX LINAC. The high‐resolution mode was used for acquisition and it required less than 1 cGy dose for each projection. The raw projections data needed background and floor image corrections and was then taken to generate tomosynthesis images by using the FDK cone‐beam reconstruction algorithm. Results: Compared with kV tomosynthesis images, MV tomosynthesis images also give good contrast for bones. However, for soft tissue, their contrast is relatively lower. We calculate normalized mutual information (NMI) between MV and kV tomosynthesis images and studied its dependence on scan angle and angular interval. The experiment shows that with the angular interval fixed, NMI increases as the scan angle grows and with the scan angle fixed, NMI decreases as the angular interval increases. For our study on a spine phantom, 50‐degree scan angle and 1‐degree angular interval gives good trade‐off between images quality and projection numbers. Conclusion: MV beam can be used to generate good quality tomosynthesis images.

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    1
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
1
Average
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!