doi: 10.1117/12.893893
Laser triangulation sensors offer a simple, non-contact and fast solution to measure displacement, position, vibration and thickness. However, these sensors are prone to target surface sensitivity since they rely heavily on a uniform back-scatter of the laser spot. Here, sources of measurement noise including surface texture, speckle, beam deflection and asymmetry are discussed. In addition, a few solutions using dithering as well as the beam shaping to reduce surface sensitivity are explored. It is shown that a simple ditherer would induce additional error and a solution is suggested to compensate for it.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 5 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |