Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Interstitial Fluid Pressurization During Confined Compression Cyclical Loading of Articular Cartilage

Authors: M A, Soltz; G A, Ateshian;

Interstitial Fluid Pressurization During Confined Compression Cyclical Loading of Articular Cartilage

Abstract

The objective of this study was to experimentally verify the well-accepted but untested hypothesis that cartilage interstitial fluid pressurizes variously under the action of an applied cyclical stress in confined compression over a range of loading frequencies, contributing significantly to the cartilage dynamic stiffness. Eighteen bovine cartilage cylindrical samples were tested under load control using a porous indenter in a confined compression chamber fitted with a microchip pressure transducer at its bottom. Over a static stress of 130 kPa, a cyclical stress of amplitude 33 kPa was applied with the indenter at frequencies ranging from 0.0001 to 0.1 Hz. The cartilage interstitial fluid pressure and deformation were measured simultaneously as a function of time. The displacement response at the lowest tested frequency was curvefitted in the time domain to determine the linear biphasic material properties, H(A) = 0.70+/-0.10 MPa and k0=2.4x10(-16)+/-0.64x10(-16) m4/N s. These properties were employed in the biphasic theory to predict the interstitial fluid pressure response and compare it to experiment, resulting in nonlinear coefficients of determination ranging from r2 = 0.89+/-0.15 to 0.96+/-0.03 depending on frequency. It was found for the samples of this study that above a characteristic frequency of 0.00044 Hz, the magnitude and phase of fluid pressurization matched the applied stress, reducing the tissue strain at the impermeable bottom surface to nearly zero. The findings of this study verify the hypothesis that cartilage dynamic stiffness derives primarily from flow-dependent viscoelasticity as predicted by the linear biphasic theory; they demonstrate experimentally the significance of interstitial fluid pressurization as the fundamental mechanism of cartilage load support over a wide range of frequencies.

Related Organizations
Keywords

Cartilage, Articular, In Vitro Techniques, Elasticity, Weight-Bearing, Reference Values, Pressure, Animals, Cattle, Stress, Mechanical, Extracellular Space, Rheology

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    193
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 1%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
193
Top 1%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!