AbstractBackgroundIt is difficult to determine the insertion length of peripherally inserted central catheters (PICCs) without fluoroscopy. The objectives of this study were to examine the relationship between the length from the anterior axillary point to the level of the carina (Lcarina) and patient's height, and to obtain possible estimation formulas that can be considered for validation in future studies.MethodsWe retrospectively analyzed PICCs from the upper arm in the pediatric intensive care unit (PICU) between May 2017 and September 2018. We evaluated the relationship between Lcarina and the patient's height using linear regression. We also conducted simulated performance assessment of simplified formulas based on the observed relationships.ResultsFifty‐four PICCs from the right arm and 49 from the left for patients at the median age of 1 year were analyzed. The following linear correlations between Lcarina and the patient's height were observed: 0.105 × height (cm) + 1.53 (cm) (P < 0.001, R2 = 0.71) from the right arm, and 0.125 × height (cm) + 1.21 (cm) (P < 0.001, R2 = 0.65) from the left arm. In the simulated performance assessment, with a simplified formula, [0.1 × height (cm) + 1 (cm)], 93% (50/54) of the PICCs from the right arm and 96% (47/49) from the left arm were expected to be inserted in the subclavian vein, innominate vein, or superior vena cava.ConclusionsThe level of the carina was correlated with the patient’s height. A simplified formula, 0.1 × height (cm) + 1, seemed to perform acceptably and appeared to be worth validating in future studies.
Catheterization, Central Venous, Catheters, Catheters, Indwelling, Vena Cava, Superior, Catheterization, Peripheral, Central Venous Catheters, Humans, Child, Retrospective Studies
Catheterization, Central Venous, Catheters, Catheters, Indwelling, Vena Cava, Superior, Catheterization, Peripheral, Central Venous Catheters, Humans, Child, Retrospective Studies
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |