
AbstractThe aim of this study was to evaluate the efficacy and safety of the stepwise mechanical transvenous lead extraction approach in a patient population with chronically implanted transvenous leads with a long dwell time.From January 2014 till December 2018, all lead extractions with lead dwell time ≥5 years performed at our tertiary centre were retrospectively analysed. A total of 173 leads, from 78 patients (median age 68 years; 81% male) with a median dwell time of 9 years (interquartile range [IQR] 5) were extracted, with three or more leads in 42% of the patients. Right atrial leads: 41%; right ventricular pacing leads: 16%; implantable cardioverter‐defibrillator (ICD) leads: 31% (72% dual coil); coronary sinus leads: 12%. The majority (75%) of the leads had an active fixation. Most frequent indication for extraction was pocket infection/erosion (76%). Overall clinical success was 97%, and complete procedural success was 93%. Venous patency, assessed with venous angiography, was well preserved in 93% of the cases. The overall procedural complication rate was 3.8% (2.6% major and 1.3% minor).Despite the complexity of the population and a very long dwell time (median 9 years), a clinical success rate of 97% was achieved with the stepwise mechanical approach. Analysis of impeding progression of pectoral extraction suggests that dense fibrosis and sharp lead curvature in the transvenous trajectory pose a challenge. Complication rate was low, and acute venous patency was generally well preserved.
Male, mechanical sheath, TightRail, Pacemaker, Artificial, cardiac implantable devices, extraction tool, Middle Aged, device-related complications, Defibrillators, Implantable, Electrodes, Implanted, transvenous lead extractions, Humans, Female, Device Removal, Aged, Retrospective Studies
Male, mechanical sheath, TightRail, Pacemaker, Artificial, cardiac implantable devices, extraction tool, Middle Aged, device-related complications, Defibrillators, Implantable, Electrodes, Implanted, transvenous lead extractions, Humans, Female, Device Removal, Aged, Retrospective Studies
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 7 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
