
doi: 10.1111/pace.13086
pmid: 28370137
AbstractBackgroundAtrial fibrillation (AF) is often treated with catheter ablation, which induces scar formation to isolate misfiring electrical signals in the left atrium. Successful ablation restores sinus rhythm at the cost of replacing viable myocardium with scar. The impact of ablation scar on mechanical function of the left atrium is poorly understood.ObjectiveWe used a computational model to simulate various ablation patterns and determine their effect on atrial global and regional mechanical function.MethodsA coupled finite‐element and hemodynamic circuit model of the left atrium that represents the regional and global mechanics in paroxysmal AF patients was modified to simulate different ablation patterns: step‐wise pulmonary vein isolation (PVI), wide area circumferential ablation (WACA), and a posterior ablation developed by nContact, Inc (Morrisville, NC, USA). Atrial pressure‐volume relationships and regional wall motion were compared among the models.ResultsAblation increased passive stiffness and decreased active work performed by the atrium. Active emptying volume decreased with increasing scar by up to 44% (11 mL) at a scar volume of 31%. At matched scar volumes, WACA decreased active emptying more severely than PVI and nContact. Similarly, wall motion was depressed most in the WACA model because WACA involved portions of the lateral wall with higher baseline motion.ConclusionSimulated ablation depressed atrial mechanical function to an extent that depended on both scar volume and location, primarily through reducing active emptying. Placing ablation scar in regions with high baseline motion resulted in greater depression of active function, while ablation of the posterior wall was less disruptive.
Cicatrix, Treatment Outcome, Heart Conduction System, Atrial Fibrillation, Models, Cardiovascular, Humans, Computer Simulation, Heart Atria, Atrial Function, Excitation Contraction Coupling
Cicatrix, Treatment Outcome, Heart Conduction System, Atrial Fibrillation, Models, Cardiovascular, Humans, Computer Simulation, Heart Atria, Atrial Function, Excitation Contraction Coupling
| citations The total number of citations received by all articles of the researcher of interest. | 19 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
