
AbstractAccording to the European Hypertension Guidelines regarding office blood pressure measurements (OBPMs), the mean between second/third or third/fourth OBPM should be taken if the first two readings differ by ≤10 or >10 mmHg, respectively. Our aim was to explore the value of the fourth OBPM and determine whether a simplified OBPM procedure is feasible without loss of quality. In this cross‐sectional study, four standard OBPMs were taken. The mean of the second/third OBPM (S2S3/D2D3) and third/fourth OBPM (S3S4/D3D4) for systolic/diastolic values was calculated. Correlation, agreement, and differences regarding BP classification were explored for the entire cohort and subsets with a difference between the first/second OBPM (S1S2/D1D2) ≤10 and >10 mmHg. Overall (n = 802) and for the subsets with an S1S2 (n = 596) and D1D2 (n = 742) difference ≤10 mmHg, S3S4/D3D4 was in median 0.5 mmHg lower than S2S3/D2D3, respectively (p < .0005 for all). In participants with an S1S2 (n = 206) and D1D2 (n = 60) difference >10 mmHg, S3S4/D3D4 differed numerically from S2S3/D2D3, respectively (p > .1 for all). Overall and for all subsets with an S1S2/D1D2 difference ≤10/>10 mmHg, less subjects were numerically classified as hypertensive with S3S4/D3D4 than with S2S3/D2D3 (p > .04), but BP reclassification occurred in both directions in 1.0%‐10.0%, depending on the cohort. In conclusion, the third/fourth OBPM results in lower BP values than the second/third measurement, regardless of the difference between first/second OBPM, whereby BP reclassifications occurred in both directions. Therefore, the cutoff of >10 versus ≤10mmHg difference between first/second OBPM to implement a fourth BPM harbors the risk of distorted results. We therefore recommend using the second/third BPM for standardized OBPM.Trial registration: Registered on clinicaltrials.gov (NCT02552030).
blood pressure measurements, arterial hypertension, Systole, blood pressure, Blood Pressure Measurement, Blood Pressure, Blood Pressure Determination, Blood Pressure Monitoring, Ambulatory, European Society of Cardiology, Cross-Sectional Studies, European Society of Hypertension, RC666-701, Hypertension, blood pressure classification, Diseases of the circulatory (Cardiovascular) system, Humans
blood pressure measurements, arterial hypertension, Systole, blood pressure, Blood Pressure Measurement, Blood Pressure, Blood Pressure Determination, Blood Pressure Monitoring, Ambulatory, European Society of Cardiology, Cross-Sectional Studies, European Society of Hypertension, RC666-701, Hypertension, blood pressure classification, Diseases of the circulatory (Cardiovascular) system, Humans
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 6 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
