
doi: 10.1111/jce.14905
pmid: 33484212
AbstractLeft bundle branch pacing (LBBP) has emerged as an alternative to His bundle pacing (HBP) to achieve physiologic ventricular stimulation. The extent of myocardial injury during permanent LBBP implantation is currently not known. The aim of the study was to prospectively assess the extent of myocardial injury during LBBP implantation. Cardiac troponin (cTn) levels were measured at baseline and 6–12 h following permanent LBBP. The number of attempts to achieve LBBP was documented. Troponin levels were measured in a control population undergoing other electrophysiology procedures including HBP, other devices involving right ventricular (RV) pacing, radiofrequency ablation for atrial fibrillation (AF) and supraventricular tachycardia (SVT). Significant elevation of troponin (SET) was defined as threefold increase above the upper reference limit (URL) for cTn. Between December 2019 and April 2020, 204 were prospectively enrolled: LBBP in 98 and Control group 106 (SVT, 55; AF, 20; HBP, 17; other devices, 14). SET (>3× URL) was seen in 49.4% of patients in the LBBP group compared to 58.4% in the control group (p = .23). Peak troponin levels were greater in the control group compared to the LBBP group (230.3 ± 320.1 vs. 87.4 ± 71.3 pg/ml; p = .0001). Compared to LBBP (49.4%), SET was observed less frequently following HBP (17.5%; p = .01), and other device implantation (29%; p = .15). Patients requiring >2 attempts (n = 33) had significantly higher incidence of SET compared to <2 attempts (n = 56; 66.7% vs. 39.3%; p = .01). LBBP implantation is associated with myocardial injury. Asymptomatic troponin release following LBBP is less than or comparable to other interventional electrophysiology procedures.
Bundle of His, Electrocardiography, Heart Conduction System, Cardiac Pacing, Artificial, Humans, Troponin
Bundle of His, Electrocardiography, Heart Conduction System, Cardiac Pacing, Artificial, Humans, Troponin
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 12 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
