
AbstractIntroductionA lead extraction difficulty (LED) score was proposed to predict the difficult transvenous lead extraction (TLE) procedures, defined by means of the fluoroscopy time. The aim of this study was to validate the estimation model based on the LED index above 10 on an independent data set of TLE cases.MethodsConsecutive patients undergoing TLE between January 2014 and January 2016 were included in this analysis. The fluoroscopy time related to the leads removal was dichotomized as above or below its 90th percentile (PCTL).ResultsIn total, 446 permanent leads were removed during 233 TLE procedures. Complete procedural success was achieved in 232 (99.1%) patients. The LED index resulted >10 in 83(35.6%) procedures. Among these cases, 20 had fluoroscopy time above the 90th PCTL (23.3 minutes) and were classified as true positive. Over the 150 procedures with LED score <10, 147 were classified as true negative, and only 3 resulted false negative. The sensitivity, the specificity, and the negative predictive value of the LED index in predicting complex cases resulted 86.9 (confidence interval [CI] 66.4–97.2)%, 70.0 (CI 63.3–76.1)%, and 98.0 (CI 94.3–99.6)%, respectively. The multivariate logistic regression analysis confirmed a 12% increased risk of high fluoroscopy for each additional point of the LED score (OR 1.12, CI 1.05–1.21, P = 0.001).ConclusionThe validation of the estimation model based on the LED index <10 confirmed its high efficacy in predicting simple TLE procedures.
Male, Femoral Vein, Middle Aged, cardiac devices; implantable cardioverter-defibrillator; lead extraction; pacemaker; Aged; Defibrillators, Implantable; Device Removal; Female; Femoral Vein; Forecasting; Humans; Male; Middle Aged; Equipment Failure, Defibrillators, Implantable, Humans, Equipment Failure, Female, Device Removal, Aged, Forecasting
Male, Femoral Vein, Middle Aged, cardiac devices; implantable cardioverter-defibrillator; lead extraction; pacemaker; Aged; Defibrillators, Implantable; Device Removal; Female; Femoral Vein; Forecasting; Humans; Male; Middle Aged; Equipment Failure, Defibrillators, Implantable, Humans, Equipment Failure, Female, Device Removal, Aged, Forecasting
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 55 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
