Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Clinical and Experim...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Clinical and Experimental Ophthalmology
Article . 2013 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
versions View all 2 versions
addClaim

Effect of phacoemulsification on trabeculectomy function

Authors: Dan Q, Nguyen; Nuwan, Niyadurupola; Robyn J, Tapp; Rachael A, O'Connell; Michael A, Coote; Jonathan G, Crowston;

Effect of phacoemulsification on trabeculectomy function

Abstract

AbstractBackgroundTo evaluate the effect of phacoemulsification on trabeculectomy function.DesignRetrospective case–control study.ParticipantsForty‐eight patients who underwent trabeculectomy surgery and had at least 2 years of follow up.MethodsPatients were classified into two groups: patients who had phacoemulsification subsequent to trabeculectomy (Trab_phaco, n = 18) and patients who were pseudophakic for greater than 6 months preceding their trabeculectomy (Phaco_trab, n = 30). Groups were matched for length of follow up of 2 years from time of trabeculectomy.Main Outcome MeasuresThe primary outcome measures were target intraocular pressure of criteria A, ≤12 mmHg; B, ≤15 mmHg; C, ≤18 mmHg with or without additional topical treatment. A separate measure for bleb function failure was also used; with failure defined as the need for additional topical antiglaucoma therapy or surgical intervention to achieve control of intraocular pressure.ResultsThere was no significant difference in achieving each intraocular pressure criterion between groups (12 months, P = 1.0; 24 months, P = 0.330). In the first 12 months, significantly more trabeculectomies in the Trab_phaco group failed, requiring additional intervention to control the IOP (39%) compared with the Phaco_trab (10%) group (P = 0.028). Although this trend continued at 24 months, there were no significant differences in failure rates (P = 0.522).ConclusionsPhacoemulsification performed after trabeculectomy significantly increased rates of bleb failure in the following 12 months but not at 24 months.

Keywords

Aged, 80 and over, Male, Phacoemulsification, Pseudophakia, Visual Acuity, Trabeculectomy, Tonometry, Ocular, Lens Implantation, Intraocular, Trabecular Meshwork, Case-Control Studies, Humans, Female, Glaucoma, Angle-Closure, Glaucoma, Open-Angle, Intraocular Pressure, Aged, Retrospective Studies

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    40
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
40
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!