Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Annals of Noninvasiv...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Annals of Noninvasive Electrocardiology
Article . 2015 . Peer-reviewed
License: Wiley Online Library User Agreement
Data sources: Crossref
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 2 versions
addClaim

Different Methods to Measure QRS Duration in CRT Patients: Impact on the Predictive Value of QRS Duration Parameters

Authors: Jan, De Pooter; Milad, El Haddad; Liesbeth, Timmers; Frédéric, Van Heuverswyn; Luc, Jordaens; Mattias, Duytschaever; Roland, Stroobandt;

Different Methods to Measure QRS Duration in CRT Patients: Impact on the Predictive Value of QRS Duration Parameters

Abstract

BackgroundMeasurements of QRS duration (QRSD) in patients undergoing cardiac resynchronization therapy (CRT) are not standardized. We hypothesized that both the measurement of QRSD and its predictive value on CRT response are sensitive to the method by which QRSD is measured.MethodsElectrocardiograms (ECGs) pre‐ and post‐CRT from 52 CRT patients (66 ± 12 years, 65% male) were retrospectively analyzed. Custom‐made software was developed to measure global QRSD (QRSDglobal) and lead‐specific QRSD (QRSDI,II,III,aVR,aVL,aVF,V1,V2,V3,V4,V5,V6). QRSD was also assessed automatic by a routinely used ECG device. For each method we measured QRSD pre‐ and post‐CRT and shortening of QRSD (∆QRSD). Response to CRT at 6 months was defined as an improvement of ≥1 class in New York Heart Association classification and an increase by >7.5% in left ventricular ejection fraction.ResultsThe CRT response rate was 77%(n = 40). Different methods to measure QRSD show divergent nominal values before (median range 152—172 ms, P < 0.001) and after CRT (130–152 ms, P < 0.001). The predictive value of QRSD measurements for CRT response also varies significantly according to the method used (range AUC pre‐CRT QRSD 0.400–0.580, P < 0.05; AUC post‐CRT QRSD 0.447–0.768, P < 0.05; AUC ΔQRSD 0.540–0.858, P < 0.05). Global QRSD measurements revealed lower variability compared to lead‐specific QRSD.ConclusionDifferent methods to measure QRSD yield not only different nominal values but also influence the value of QRSD in predicting CRT response. Measuring QRSD by a global method can help to standardize QRSD measurements in future studies.

Related Organizations
Keywords

Male, Middle Aged, Cardiac Resynchronization Therapy, Electrocardiography, Ventricular Dysfunction, Left, Echocardiography, Heart Conduction System, Predictive Value of Tests, Humans, Female, Software, Aged, Retrospective Studies

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    27
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
27
Top 10%
Top 10%
Top 10%
gold