BackgroundThe aim of the study is to contrast the role of conventional ambulatory electrocardiographic monitoring (AEM) artifacts with a less emphasized problem with potentially more serious implications, that is, the failure to recognize, and therefore misinterpret, a genuine arrhythmia episode in the AEM recording.MethodsThe study material included 500 Holter recordings and 500 recordings from the cardiac telemetry unit.ResultsElectrocardiographic (ECG) artifacts were more common in telemetry recordings (5.6%) compared to Holter recordings (4%) for a total of 4.8%. There were 35 examples of misinterpretation of AEM recordings (3.5%). These were significantly more common in telemetry recordings (2.6%) compared to Holter recordings (0.9%). The most common ECG artifacts were examples of pseudo ventricular tachyarrhythmia (VT). The majority of misinterpretation (26 of 35 examples) were fast supraventricular tachyarrhythmias with aberrant QRS (including six examples of atrial flutter with periods of 1:1 atrioventricular conduction) that were misdiagnosed as ventricular VT. Other examples were misinterpretation of arrhythmic episodes consistent with sick sinus syndrome, pacemaker malfunction, and long QT syndrome. Only 5 of 48 examples of AEM artifacts resulted in management errors of commission or errors of omission compared to all 35 examples of misinterpretation.ConclusionsCompared to conventional artifacts in AEM, misinterpretation of nonartifactual arrhythmic episodes consistently resulted in management errors. Misinterpretation was significantly more common with telemetry recordings compared to Holter ECG. This highlights the need for more appropriate training of the entire clinical team in charge of the management of the cardiac telemetry unit.
Adult, Male, Young Adult, Electrocardiography, Ambulatory, Humans, Arrhythmias, Cardiac, Female, Diagnostic Errors, Middle Aged, Artifacts, Aged
Adult, Male, Young Adult, Electrocardiography, Ambulatory, Humans, Arrhythmias, Cardiac, Female, Diagnostic Errors, Middle Aged, Artifacts, Aged
| citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 8 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |