These instructions give you basic electromagnetic force on an arcing contact is one of the principal factors in designing large-capacity and small-sized high current contact systems of circuit breakers, disconnectors or isolated switches. Butt contacts, such as those in vacuum interrupters, tulip contacts structured from a rod contact and fingers are adopted widely in gas circuit breakers. In this paper, results of the detailed evaluation of current distributions and electromagnetic forces are described with three-dimensional electromagnetic field analysis were applied to a finite element model of a butt and tulip contacts.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 4 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |