Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao IEEE Transactions on...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Article . 2015 . Peer-reviewed
License: IEEE Copyright
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Coherent compounding in doppler imaging

Authors: Ingvild K, Ekroll; Marco M, Voormolen; Oyvind K-V, Standal; Jochen M, Rau; Lasse, Lovstakken;

Coherent compounding in doppler imaging

Abstract

Coherent compounding can provide high frame rates and wide regions of interest for imaging of blood flow. However, motion will cause out-of-phase summation, potentially causing image degradation. In this work the impact of blood motion on SNR and the accuracy of Doppler velocity estimates are investigated. A simplified model for the compounded Doppler signal is proposed. The model is used to show that coherent compounding acts as a low-pass filter on the coherent compounding Doppler signal, resulting in negatively biased velocity estimates. Simulations and flow phantom experiments are used to quantify the bias and Doppler SNR for different velocities and beam-to-flow (BTF) angles. It is shown that the bias in the mean velocity increases with increasing beam-to-flow angle and/or blood velocity, whereas the SNR decreases; losses up to 4 dB were observed in the investigated scenarios. Further, a 2-D motion correction scheme is proposed based on multi-angle vector Doppler velocity estimates. For a velocity of 1.1 v(Nyq) and a BTF angle of 75°, the bias was reduced from 30% to less than 4% in simulations. The motion correction scheme was also applied to flow phantom and in vivo recordings, in both cases resulting in a substantially reduced mean velocity bias and an SNR less dependent on blood velocity and direction.

Keywords

Carotid Artery, Common, Phantoms, Imaging, Humans, Signal Processing, Computer-Assisted, Blood Flow Velocity, Echocardiography, Doppler

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    42
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
42
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!