Total ionizing dose effects in a low-dropout voltage regulator are explained based on experimental data and circuit simulations. Transistor gain degradation is shown to be the dominant cause of the circuit degradation at lower dose rates. In addition, collector-to-emitter leakage current in one of the NPN transistors of the bandgap reference part of the circuit is responsible for increasing the postirradiation output voltage at high dose rates. Parametric changes in the bandgap, differential amplifier, and output pass transistor circuit blocks are identified that are responsible for various aspects of the observed circuit degradation. The different annealing characteristics of oxide-trap and interface-trap charge are responsible for the complex postirradiation recovery of the output voltage
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 17 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |