A wet thermal paper method for measuring of mode patterns and heat distributions in a high-power microwave multimode cavity is developed. The exposure time of the paper is evaluated. It is shown that this method allows measuring and recording mode patterns in the loaded and unloaded cavity, and the heat distribution inside the cavity with a load movement. The mode patterns and heat distributions along horizontal and vertical planes of the cavity are presented. Possible applications of the method in medicine and biology are discussed, and a calibration protocol of a microwave oven for microwave radiation exposure on cell cultures in the cavity is given.
Measurement, Microwave cavity, Exposure time, power measurement, Mode patterns, protocols, -, calibration, microwaves, microwave ovens, electromagnetic heating, frequency, Calibration, Wet thermal paper method, High power
Measurement, Microwave cavity, Exposure time, power measurement, Mode patterns, protocols, -, calibration, microwaves, microwave ovens, electromagnetic heating, frequency, Calibration, Wet thermal paper method, High power
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 16 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |