Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao IEEE Transactions on...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
IEEE Transactions on Biomedical Engineering
Article . 2020 . Peer-reviewed
License: IEEE Copyright
Data sources: Crossref
DBLP
Article . 2020
Data sources: DBLP
versions View all 3 versions
addClaim

Wireless Interrogation of Implantable SAW Sensors

Authors: Longfang Zou; Christopher McLeod; Mohammad Reza Bahmanyar;

Wireless Interrogation of Implantable SAW Sensors

Abstract

Implantable sensors provide long-term, accurate physiological measurements after a minimally invasive procedure, particularly when designed as transponders. Wireless interrogation of deeply implanted transponders with RF remains a challenge due to the high loss at the skin-air interface and large tissue RF absorption. This paper presents a system for wirelessly interrogating surface acoustic wave (SAW) sensors implanted in the main pulmonary artery (PA), where the pressure (PAP) is a very important parameter in the management of heart failure patients. The proposed PAP monitoring system consists of an implantable SAW pressure sensor integrated with an antenna and anchor in a housing, an external antenna and an electronic interrogator. The PAP is determined by measuring the frequency of the echo signal from SAW sensor accurately. An asymmetric antenna was designed and integrated with the sensor. The combination of simulation, theoretical calculation and phantom measurement indicates that the path loss to the implant location, about 6 cm below the skin, is around 25 dB. A portable interrogator was designed based on a dual conversion receiver and single echo high frequency sampling approach to assess achievable frequency estimation accuracy predicted by Cramer-Rao Lower Bound (CRLB) analysis. The system was characterized using a high quality (Q) factor SAW sensor, fabricated at wafer level, wire-connected to the interrogator via an attenuator to simulate path loss. The signal-to-noise ratio (SNR) of captured echo signals was calculated and used in CRLB analysis. The analysis indicates that without using signal post processing, the sensor sensitivity has to be at least 440 Hz/mmHg in order to achieve a target 1 mmHg accuracy. Although the current sensor sensitivity is only 200 Hz/mmHg, the in vivo measurement showed that acceptable accuracy can be obtained by signal post processing. The results from an invasive catheter tip transducer measured simultaneously with the SAW sensor showed that the differences in pulse pressure and relative mean pressure are 0.8 mmHg and 1.4 mmHg, respectively. The accuracy could be further improved by increasing the sensor Q factor and sensitivity and reducing path loss.

Related Organizations
Keywords

Sound, Transducers, Humans, Prostheses and Implants, Electronics, Monitoring, Physiologic

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    19
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
19
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!