Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao IEEE Transactions on...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
IEEE Transactions on Biomedical Engineering
Article . 2014 . Peer-reviewed
License: IEEE Copyright
Data sources: Crossref
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
DBLP
Article . 2020
Data sources: DBLP
versions View all 4 versions
addClaim

Modeling the Glucose Sensor Error

Authors: FACCHINETTI, ANDREA; DEL FAVERO, SIMONE; SPARACINO, GIOVANNI; Jessica Castle; Kenneth W. Ward; COBELLI, CLAUDIO;

Modeling the Glucose Sensor Error

Abstract

Continuous glucose monitoring (CGM) sensors are portable devices, employed in the treatment of diabetes, able to measure glucose concentration in the interstitium almost continuously for several days. However, CGM sensors are not as accurate as standard blood glucose (BG) meters. Studies comparing CGM versus BG demonstrated that CGM is affected by distortion due to diffusion processes and by time-varying systematic under/overestimations due to calibrations and sensor drifts. In addition, measurement noise is also present in CGM data. A reliable model of the different components of CGM inaccuracy with respect to BG (briefly, "sensor error") is important in several applications, e.g., design of optimal digital filters for denoising of CGM data, real-time glucose prediction, insulin dosing, and artificial pancreas control algorithms. The aim of this paper is to propose an approach to describe CGM sensor error by exploiting n multiple simultaneous CGM recordings. The model of sensor error description includes a model of blood-to-interstitial glucose diffusion process, a linear time-varying model to account for calibration and sensor drift-in-time, and an autoregressive model to describe the additive measurement noise. Model orders and parameters are identified from the n simultaneous CGM sensor recordings and BG references. While the model is applicable to any CGM sensor, here, it is used on a database of 36 datasets of type 1 diabetic adults in which n = 4 Dexcom SEVEN Plus CGM time series and frequent BG references were available simultaneously. Results demonstrates that multiple simultaneous sensor data and proper modeling allow dissecting the sensor error into its different components, distinguishing those related to physiology from those related to technology.

Country
Italy
Related Organizations
Keywords

Blood Glucose, Diabetes Mellitus, Type 1, Databases, Factual, Calibration, Humans, Monitoring, Ambulatory, Models, Biological, Algorithms

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    107
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 1%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
107
Top 10%
Top 10%
Top 1%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!