New function for approximating electrostatic discharge current given in IEC 61000-4-2 Standard is presented in this paper. Its parameters are determined in order to set requirements for the test generator currents. The results are compared to results of other functions from literature. The main advantage is that maximum current values and corresponding time moments are chosen in advance, and other parameters are determined using least-squares method.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |