Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao IEEE Journal of Biom...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
IEEE Journal of Biomedical and Health Informatics
Article . 2023 . Peer-reviewed
License: IEEE Copyright
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Impedance-Based Ventilation Detection and Signal Quality Control During Out-of-Hospital Cardiopulmonary Resuscitation

Authors: Xabier Jaureguibeitia; Elisabete Aramendi; Henry E. Wang; Ahamed H. Idris;

Impedance-Based Ventilation Detection and Signal Quality Control During Out-of-Hospital Cardiopulmonary Resuscitation

Abstract

Feedback on ventilation could help improve cardiopulmonary resuscitation quality and survival from out-of-hospital cardiac arrest (OHCA). However, current technology that monitors ventilation during OHCA is very limited. Thoracic impedance (TI) is sensitive to air volume changes in the lungs, allowing ventilations to be identified, but is affected by artifacts due to chest compressions and electrode motion. This study introduces a novel algorithm to identify ventilations in TI during continuous chest compressions in OHCA. Data from 367 OHCA patients were included, and 2551 one-minute TI segments were extracted. Concurrent capnography data were used to annotate 20724 ground truth ventilations for training and evaluation. A three-step procedure was applied to each TI segment: First, bidirectional static and adaptive filters were applied to remove compression artifacts. Then, fluctuations potentially due to ventilations were located and characterized. Finally, a recurrent neural network was used to discriminate ventilations from other spurious fluctuations. A quality control stage was also developed to anticipate segments where ventilation detection could be compromised. The algorithm was trained and tested using 5-fold cross-validation, and outperformed previous solutions in the literature on the study dataset. The median (interquartile range, IQR) per-segment and per-patient F 1-scores were 89.1 (70.8-99.6) and 84.1 (69.0-93.9), respectively. The quality control stage identified most low performance segments. For the 50% of segments with highest quality scores, the median per-segment and per-patient F 1-scores were 100.0 (90.9-100.0) and 94.3 (86.5-97.8). The proposed algorithm could allow reliable, quality-conditioned feedback on ventilation in the challenging scenario of continuous manual CPR in OHCA.

Keywords

Quality Control, Electric Impedance, Humans, Lung, Cardiopulmonary Resuscitation, Ventilation, Out-of-Hospital Cardiac Arrest, Hospitals

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    4
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
4
Top 10%
Average
Average
Related to Research communities
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!