Touch voltage protection on Singapore MRT system

Authors: W.M. Sim; M. Thong; C.F. Chan;

Touch voltage protection on Singapore MRT system

Abstract

This paper generally describes the various touch voltage protection measures adopted mass rapid transit (MRT) systems. Particular reference is drawn from the practices adopted in the Singapore MRT system. There are potential hazards of electric shocks to passengers and working staff touching conductive surfaces of different voltage potentials e.g. around the platform edge particularly between the platform screen doors and train or train depot workshop area. As such, there is a need to address this concern through the application of appropriate touch voltage protection. It is recognised that prior to examining the earth (grounding) details, an important but often obscure concept of touch voltage protection must be fully understood and considered to ensure that the touch voltage protection have been properly catered for to mitigate the potential hazard. This paper also outlined the touch voltage protection methods adopted in the existing Singapore MRT depot areas. Problems experienced on touch voltage protection issues in existing Singapore MRT system are also highlighted. Provisions of touch voltage protection devices i.e. running rails to earth voltage limiting device (64P relay) and fault voltage monitoring equipment (FVME) are also discussed in the paper. Various civil provisions for touch voltage protection issues at stations especially at those stations with platform edge columns are also covered. In addition, the paper also outlines the adopted integrity measurements for installations within the protection zone for the required touch voltage protection purposes

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    3
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
3
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!