Tripping and slipping are serious health concerns for the elderly because they result in life threatening injuries i.e., fractures and high medical costs. Our recent work in detection of tripping gait patterns has demonstrated that minimum toe clearance (MTC) is a sensitive falls risk predictor. MTC measurement has previously been done in gait laboratories and on treadmills which potentially imposes controlled walking conditions. In this paper, we describe a prototype design of a wireless device for monitoring vertical toe clearance. The sensors consists of a tri-axis accelerometer and dual-axis gyroscope connected to Crossbow sensor motes for wireless data transmission. Sensor data are transmitted to a laptop and displayed on a Matlab graphic user interface (GUI). We have performed zero base and treadmill experiments to investigate sensor performance to environmental variations and compared the calculated toe clearance against measurements made by an Optotrak motion system. It was found that device outputs were approximately independent of small ambient temperature variations, had a reliable range of 20m indoors and 50m outdoors and a maximum transmission rate of 20 packets/s. Toe clearance measurements were found to follow the Optotrak measurement trend but could be improved further by dealing with double integration errors and improving data transmission rates.
health concerns for elderly, Acceleration, Transducers, 610, Monitoring, Ambulatory, Pilot Projects, Sensitivity and Specificity, 0903 Biomedical Engineering, minimum toe clearance (MTC), Humans, Telemetry, detection of tripping gait patterns, Gait, Rehabilitation, Reproducibility of Results, Equipment Design, tripping, Toes, 620, Exercise & Sport Science (CARES), Equipment Failure Analysis, Centre for Ageing, falls risk predictor, prototype design of wireless device for monitoring vertical toe clearance, ResPubID16462, Accidental Falls, 1106 Human Movement and Sports Science, slipping
health concerns for elderly, Acceleration, Transducers, 610, Monitoring, Ambulatory, Pilot Projects, Sensitivity and Specificity, 0903 Biomedical Engineering, minimum toe clearance (MTC), Humans, Telemetry, detection of tripping gait patterns, Gait, Rehabilitation, Reproducibility of Results, Equipment Design, tripping, Toes, 620, Exercise & Sport Science (CARES), Equipment Failure Analysis, Centre for Ageing, falls risk predictor, prototype design of wireless device for monitoring vertical toe clearance, ResPubID16462, Accidental Falls, 1106 Human Movement and Sports Science, slipping
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 11 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |