Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao https://doi.org/10.1...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
https://doi.org/10.1109/embc.2...
Article . 2019 . Peer-reviewed
License: IEEE Copyright
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Impedance Based Automatic Detection of Ventilations During Mechanical Cardiopulmonary Resuscitation

Authors: Pamela Owens; Henry E. Wang; Elisabete Aramendi; Unai Irusta; Xabier Jaureguibeitia; Erik Alonso; Ahamed H. Idris;

Impedance Based Automatic Detection of Ventilations During Mechanical Cardiopulmonary Resuscitation

Abstract

Monitoring ventilation rate is key to improve the quality of cardiopulmonary resuscitation (CPR) and increase the probability of survival in the event of an out-of-hospital cardiac arrest (OHCA). Ventilations produce discernible fluctuations in the thoracic impedance signal recorded by defibrillators. Impedance-based detection of ventilations during CPR is challenging due to chest compression artifacts. This study presents a method for an accurate detection of ventilations when chest compressions are delivered using a piston-driven mechanical device. Data from 223 OHCA patients were analyzed and 399 analysis segments totaling 3101 minutes of mechanical CPR were extracted. A total of 18327 ventilations were annotated using concurrent capnogram recordings. An adaptive least mean squares filter was used to remove compression artifacts. Potential ventilations were detected using a greedy peak detector, and the ventilation waveform was characterized using 8 waveform features. These features were used in a logistic regression classifier to discriminate true ventilations from false positives produced by the greedy peak detector. The classifier was trained and tested using patient wise 10-fold cross validation (CV), and 100 random CV partitions were created to statistically characterize the performance metrics. The peak detector presented a sensitivity (Se) of 99.30%, but a positive predictive value (PPV) of 54.43%. The best classifier configuration used 6 features and improved the mean (sd) Se and PPV of the detector to 93.20% (0.06) and 94.43% (0.04), respectively. When used to measure per minute ventilation rates for feedback to the rescuer, the mean (sd) absolute error in ventilation rate was 0.61 (1.64) min-1. The first impedance-based method to accurately detect ventilations and give feedback on ventilation rate during mechanical CPR has been demonstrated.

Keywords

Electric Impedance, Humans, Cardiopulmonary Resuscitation, Out-of-Hospital Cardiac Arrest, Ventilation, Defibrillators

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    2
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
2
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!