A reconfiguration technique for cascaded H-bridge multilevel inverter drives (CMID) is proposed in this paper. The reliability of the CMID can be improved by using the proposed reconfiguration technique. The proposed technique is very simple to implement because the proposed technique is based on digital logic gate; a simple AND gate and OR gate can be implemented for this reconfiguration method. The effects and limitations of using the developed reconfiguration technique at high modulation index are also addressed.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 2 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |