Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao IEEE Transactions on...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
IEEE Transactions on Rehabilitation Engineering
Article . 1998 . Peer-reviewed
License: IEEE Copyright
Data sources: Crossref
versions View all 2 versions
addClaim

A transducer for the measurement of finger joint moments

Authors: K L, Kilgore; R T, Lauer; P H, Peckham;

A transducer for the measurement of finger joint moments

Abstract

A device capable of simultaneously measuring the isometric moments generated about the metacarpophalangeal (MP), proximal interphalangeal (PIP), and distal interphalangeal (DIP) joints of all four fingers has been developed. The design utilizes a four-bar linkage to transmit moments, but not forces, to the device. This linkage allows the same device to fit a wide range of hand sizes without recalibration. The device was constructed out of aluminum bars which are strapped to each joint segment and to the back of the hand. Strain gauges mounted to the aluminum bars measure the bending moment on the device, which is directly related to the moment applied about the joint center of rotation. Because of the unique design of the device, it is not necessary to have accurate measurements of the joint center of rotation in order to get accurate moment information. A single device is capable of generating independent measurement of MP extension/flexion, PIP extension/flexion, and DIP extension/flexion. Four of these devices can be used to make simultaneous measurements of all the moments generated by all four fingers. The device also acts as a splint, allowing each joint to be positioned and locked at any angle through the range of motion of the joint. The device is accurate to within +/- 5.6% of each reading for moments from 10 N x cm to 100 N x cm and within +/- 2.0 N x cm for moments of 10 N x cm or less. If the device configuration is constrained, the accuracy can be improved to +/- 0.8% of full scale (100 N x cm) and +/- 0.21 N x cm for moments of 10 N x cm or less. The device can measure both flexion and extension moments up to 100 N x cm, and can allow the joints to be fixed at any angle from approximately 10 to 80 degrees.

Related Organizations
Keywords

Finger Joint, Calibration, Transducers, Biophysics, Humans, Range of Motion, Articular, Biophysical Phenomena

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    16
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
16
Average
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!