It is known that the breakdown voltage in a vacuum insulation system drops with an increase in linear dimension of electrodes and with an increase in the number of insulating spacers bridging the gap. Normally this is explained to be the result of the increase in the number of so-called weak links in the system. The influence of an external capacitance on the flashover voltage of an electrode gap bridged by a spacer was investigated. When a capacitor was connected inside the vacuum chamber near the discharge site in parallel with the gap, it was found that the additional capacitance lowered the breakdown voltage in a manner similar to that observed with an increase in electrode area. This supports the energy explanation of the area effect. A larger external capacitor, far from the discharge site, had no influence on the breakdown voltage. >
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 8 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |