Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Personal dose equivalent angular response factors for photons with energies up to 1 GeV

Authors: K G, Veinot;

Personal dose equivalent angular response factors for photons with energies up to 1 GeV

Abstract

When performing personal dosemeter calibrations, the dosemeters are typically irradiated while mounted on slab-type phantoms and oriented facing the source. Performance testing standards or intercomparison studies may also specify various rotational angles to test the response of the dosemeter and associated algorithm as this rotation introduces changes in the quantity of delivered dose. Correction factors for rotational effects are available, but many have not been updated in recent years and were typically calculated using the kerma approximation. The personal dose equivalent, Hp(d), is the quantity recommended by the International Commission on Radiation Units and Measurements to be used as an approximation of the protection quantity effective dose when performing personal dosemeter calibrations. The personal dose equivalent can be defined for any location and depth within the body, but typically the location of interest is the trunk where personal dosemeters are worn and in this instance a suitable approximation is a 30 cm × 30 cm × 15 cm slab-type phantom. In this work personal dose equivalent conversion coefficients for photons with energies up to 1 GeV have been calculated for depths of 0.007, 0.3 and 1.0 cm in the slab phantom for rotational angles ranging from 15° to 75°. Angular response factors have been determined by comparing the conversion coefficients for each angle and energy to those reported in an earlier work for a non-rotational (e.g. perpendicular to the phantom face) geometry. The angular response factors were determined for discrete angles, but fits of the factors are provided.

Related Organizations
Keywords

Photons, Radiation Protection, Phantoms, Imaging, Radiation Monitoring, Electromagnetic Radiation, Humans, Radiation Dosage, Algorithms, Relative Biological Effectiveness

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    1
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
1
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!