Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Radiation Protection...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Radiation Protection Dosimetry
Article . 2025 . Peer-reviewed
License: OUP Standard Publication Reuse
Data sources: Crossref
versions View all 2 versions
addClaim

Cost-effective shielding design based on the dose length product method for shielding calculations in X-ray computed tomography systems

Authors: Kimiya Noto; Wataru Mitsui; Tadanori Takata; Hironori Kojima; Kosuke Matsubara; Ichiro Yamaguchi;

Cost-effective shielding design based on the dose length product method for shielding calculations in X-ray computed tomography systems

Abstract

Abstract In medical facilities, pre-shielding calculations are essential when introducing new X-ray equipment to protect the staff from radiation. For computed tomography (CT), the dose length product (DLP) method is commonly used for shielding calculations. This method allows the evaluation of the dose at any wall position. This study proposed a cost-effective design for CT room shielding, adjusting the material thickness based on the operator’s exposure and the room’s environment. Scattered radiation was measured using an optically stimulated luminescence dosemeter. The calculated values were 2.0 to 7.5 times higher than the measured values inside the CT room, confirming the accuracy of the DLP method in estimating the actual dose. No scattered radiation was detected outside the CT room. This study demonstrates that the DLP method enables pre-installation shielding calculations that balance cost and safety.

Keywords

Radiation Protection, Phantoms, Imaging, Cost-Benefit Analysis, Occupational Exposure, Humans, Scattering, Radiation, Equipment Design, Tomography, X-Ray Computed, Radiation Dosage

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!