Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Radiation Protection...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Radiation Protection Dosimetry
Article . 2020 . Peer-reviewed
License: OUP Standard Publication Reuse
Data sources: Crossref
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
versions View all 3 versions
addClaim

TOWARDS NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR MAMMOGRAPHY IN SERBIA

Authors: Rafajlović, Stefan; Ciraj-Bjelac, Olivera; Božović, Predrag;

TOWARDS NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR MAMMOGRAPHY IN SERBIA

Abstract

Abstract The objective of this work is to investigate the possibility to set a national diagnostic reference levels (nDRLs) for diagnostic and screening mammography in Serbia based on local practice and available resources. This study included all types of mammography systems that are currently used in Serbia, namely screen-film mammography (SFM), computed radiography (CR) and full-field digital mammography (FFDM). The nDRLs are provided in terms of mean glandular dose (MGD) for different breast thicknesses simulated by polymethyl methacrylate (PMMA) phantom. For each breast thickness, MGD was calculated for the X-ray tube output, using clinically used exposure parameters. DRLs were chosen as the 75th percentile of MGD distribution for 20-, 40-, 45-, 60- and 70-mm phantom thicknesses. For SFM units proposed nDRL values are 0.7, 2.1, 2.7, 4.6 and 6.8 mGy; for CR units proposed nDRL values are 0.7, 1.8, 2.4, 4.5 and 5.6 mGy; and corresponding values for FFDM units are 0.8, 1.7, 2, 2. and 3.2 mGy for 20-, 40-, 45-, 60- and 70-mm PMMA thickness, respectively.

Country
Serbia
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    3
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 51
  • 51
    views
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
3
Average
Average
Average
51
hybrid