
Abstract Background The key correlate of protection of respiratory syncytial virus (RSV) vaccines and monoclonal antibodies (mAbs) is virus neutralization, measured via sera obtained through venipuncture. Dried blood obtained with a finger prick can simplify acquisition, processing, storage, and transport in trials and thereby reduce costs. In this study, we validate an assay to measure RSV neutralization in dried capillary blood. Methods Functional antibodies were compared between matched serum and dried blood samples from a phase 1 trial with RSM01, an investigational anti-RSV prefusion F mAb. Hep-2 cells were infected with a serial dilution of sample-virus mixture by using RSV-A2-mKate to determine the half-maximal inhibitory concentration. Stability of dried blood was evaluated over time and during temperature stress. Results Functional antibodies in dried blood were highly correlated with serum (R2 = 0.98, P < .0001). The precision of the assay for dried blood was similar to serum. The function of mAb remained stable for 9 months at room temperature and frozen dried blood samples. Conclusions We demonstrated the feasibility of measuring RSV neutralization using dried blood as a patient-centered solution that may replace serology testing in trials against RSV or other viruses, such as influenza and SARS-CoV-2. Clinical Trials Registration. NCT05118386 (ClinicalTrials.gov).
clinical trials, dried blood, respiratory syncytial virus, Antibodies, Monoclonal, General Medicine, Respiratory Syncytial Virus Infections, Antibodies, Viral, Antibodies, Neutralizing, Neutralization Tests, vaccine, Respiratory Syncytial Virus, Human, Journal Article, Major Article, antibodies, Humans, Dried Blood Spot Testing
clinical trials, dried blood, respiratory syncytial virus, Antibodies, Monoclonal, General Medicine, Respiratory Syncytial Virus Infections, Antibodies, Viral, Antibodies, Neutralizing, Neutralization Tests, vaccine, Respiratory Syncytial Virus, Human, Journal Article, Major Article, antibodies, Humans, Dried Blood Spot Testing
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 6 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
