Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Lymphatic Research a...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Lymphatic Research and Biology
Article . 2011 . Peer-reviewed
License: Mary Ann Liebert TDM
Data sources: Crossref
versions View all 2 versions
addClaim

Inter-Rater Reliability of Arm Circumference Measurement

Authors: Nasim, Foroughi; Elizabeth S, Dylke; Ross D, Paterson; Kristine A, Sparrow; Jacqueline, Fan; Elise B G, Warwick; Sharon L, Kilbreath;

Inter-Rater Reliability of Arm Circumference Measurement

Abstract

Arm lymphedema is routinely assessed by clinicians and researchers, using arm circumference measurements. A protocol was developed for measuring arm circumference independent of medically trained professionals. The aim of this project was to assess the protocol's inter-rater reliability and its coherence with perometry measures.Community-dwelling adults (n = 57), aged 60.2 ± 12.8 years, in good general health, were included in this study. Circumference of both arms were measured at the ulnar styloid of the wrist and at four 10 cm intervals up the arm by a friend of the participant, as well as the trained assessor using a tape measure. The same measures were also obtained with a perometer. The assessment tools had moderate to high concordance (r(c) = 0.84-0.94 for assessor vs. perometer and r(c) = 0.68-0.93 for assessor vs. participant). Limits of agreement analysis revealed that the mean difference between methods varied based on the measurement location; the bias ranged from -5.5% to 1.5% for assessor-measured vs. perometer methods and from -2.4% to 4.0% for assessor-measured vs. participant-measured methods.The written instructions and cartoons are reliable tools that could be used by women at risk of lymphedema as well as those with lymphedema following treatment for breast cancer to measure their arm circumference reliably independent of medically trained personnel.

Related Organizations
Keywords

Observer Variation, Cross-Sectional Studies, Anthropometry, Arm, Humans, Reproducibility of Results, Middle Aged, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    22
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
22
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!