pmid: 30524089
In this work we compare spatially variant radioisotope-specific point spread functions (PSFs) derived from published positron range data with measured data using a high resolution research tomograph (HRRT). Spatially variant PSFs were measured on a HRRT for fluorine-18, carbon-11 and gallium-68 using an array of printed point sources. For gallium-68, this required modification of the original design to handle its longer positron range. Using the fluorine-18 measurements and previously published data from Monte-Carlo simulations of positron range, estimated PSFs for carbon-11 and gallium-68 were calculated and compared with experimental data. A double 3D Gaussian function was fitted to the estimated and measured data and used to model the spatially varying PSFs over the scanner field of view (FOV). Differences between the measured and estimated PSFs were quantified using the full-width-at-half-maximum (FWHM) and full-width-at-tenth-maximum (FWTM) in the tangential, radial and axial directions. While estimated PSFs were generally in agreement with the measured PSFs over the entire FOV better agreement was observed (FWHM and FWTM differences of less than 10%) when using one of the two sets of positron range simulations, especially for gallium-68 and for the FWTM. Spatially variant radioisotope specific PSFs can be accurately estimated from fluorine-18 measurements and published positron range data. We have experimentally validated this approach for carbon-11 and gallium-68, and such an approach may be applicable to other radioisotopes such as oxygen-15 for which measurements are not practical.
Fluorine Radioisotopes, high resolution PET, Phantoms, Imaging, Electrons, Gallium Radioisotopes, point spread function, PET, Oxygen Radioisotopes, Positron-Emission Tomography, Image Processing, Computer-Assisted, Humans, Computer Simulation, Carbon Radioisotopes, positron range, spatial resolution, Monte Carlo Method
Fluorine Radioisotopes, high resolution PET, Phantoms, Imaging, Electrons, Gallium Radioisotopes, point spread function, PET, Oxygen Radioisotopes, Positron-Emission Tomography, Image Processing, Computer-Assisted, Humans, Computer Simulation, Carbon Radioisotopes, positron range, spatial resolution, Monte Carlo Method
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 4 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |